RIL’s commitment to quality is fundamental in everything that we do – from manufacturing to customer service, constantly meeting our customer needs and expectations is a mantra that runs to the core of the business. Certification to recognized standards for Quality Management Systems has been the norm of RIL since inception. A culture of continuous improvement ensures the company’s systems are constantly updated. To that end, we consider every cylinder to be a reflection of the brand “Refex”.

RIL provides each customer with a certificate of Analysis that conforms to ARI700 standards. Additionally, while rebottling, the products filled are tested and analyzed before and after filling in our state of the art laboratory.

The Refrigerant Analyzer is used for checking the product, the Gas Chromatograph checks the purity of the Refrigerant, other permissible impurities and any non-condensable gases and the Moisture Analyzer checks the moisture content in the refrigerant. Furthermore, RIL has been certified with ISO 9001-2000 accreditation by TUV-SUD, Germany.

Special precautions taken for cylinders, like our cylinder refurbishment system, have become a benchmark in the industry. Refex offers these and other cylinder refurbishing services :

  • Internal cleaning
  • Internal drying
  • Removal of old paint
  • Valve replacement

Cylinder Cleaning Process

  • Ensure the pressure is neutralized
  • Open the valve and remove the gas, check valve for any damage in the thread.
  • Check the cylinder conditions outside and inside through Light Bulb
  • Classify the cylinder as reusable or not based on the rust content and scrap the cylinder which are rusted beyond use.
  • Clean inside the cylinder using a magnetic rod to remove small rust and iron particles.
  • Use a vaccum cleaner to remove non-iron particles and foreign particles from the cylinder, ensure all foreign particles are removed.
  • Use 141b to remove any oil from the cylinder
  • Check with Light bulb for final inspection
  • Replace the Teflon tape on the valve.
  • Tighten the valve and replace the cap and send the cylinder to serial vacuuming centre

Tonner cleaning process

  • Ensure the pressure is neutralized
  • Open the valve and remove the gas, check valve for any damage in the thread.
  • Purge the tonner with Nitrogen under pressure and flush out the contents of the same.
  • Remove the valve and check for any rust or oil, if so use a magnetic rod to clean the rust and R141b to remove oil.
  • Replace the Teflon tape in the valve.
  • Tighten the valve and replace the cap and send the cylinder to serial vaccuming centre

Painting of cylinders

  • Check whether dealers sent any other brand cylinders
  • If yes, clean the cylinder outside and apply Refex brand colour
  • Apply appropriate product name stencil on painted cylinder for identification
What is Refrigerants Analyser?

Refrigerant Analyser is an instrument used to identify name of refrigerant, mixtures of contents present in it and identifying the purity of products.